當(dāng)前位置:首頁  >  技術(shù)文章  >  HP-RFS300A The thermal paper standard static color tester

HP-RFS300A The thermal paper standard static color tester

更新時間:2024-09-23      點(diǎn)擊次數(shù):522

Product Introduction:

The thermal paper standard static color tester is mainly used to quickly test the thermal reaction state of thermal materials under different conditions, in order to verify the thermal quality of thermal materials or to detect the optimal thermal parameters of thermal materials. It is an essential testing equipment for thermal sensitive material production units, users, and quality control departments. Meet GB/T28210-2011 thermal paper, QB/T2694 lottery paper.

 

Working principle:

 

The thermal reaction tester adopts the hot pressure detection method, placing the thermosensitive material between the upper and lower heating blocks, and then closing the upper and lower heating blocks to heat the thermosensitive material. The heating time, temperature of the heating block, and closing pressure of the heating block can be adjusted, allowing for rapid evaluation of different test samples. This instrument is controlled by a fixed program and has simple settings. It can be used to detect different thermosensitive materials, and can also be used to determine the ideal thermosensitive parameters for a specific thermosensitive material, providing users with accurate thermosensitive indicators.

Technical indicators:

1. Thermally sensitive temperature at room temperature+10 ° C to 250 ° C

2. Thermally sensitive pressure: 0.05-0.7MPa

3. Thermal sensitivity time: 0.1~999.9 seconds

4. Temperature gradient 20

5 heating surfaces 330mm x 10mm (customizable)

6. Gas source pressure 0.7MPa

7. External dimensions: 500mm x 330mm x 470mm (L x B x H)

 

8 power supply AC 220V ± 10% 50Hz

9 Net weight 30kg

Technical features:

The thermal reaction tester is based on the principle of thermal discoloration of thermosensitive materials, using heating blocks designed according to national and international standards. It is specialized in measuring the thermal discoloration status of various thermosensitive materials and the degree of discoloration under different working conditions, thereby guiding large-scale industrial production. This instrument mainly includes the following characteristics:

1. Number P I. D temperature control technology can not only quickly reach the set temperature, but also effectively avoid temperature fluctuations

2. Wide range temperature, pressure, and time control can meet various testing conditions of users

3. The manual and foot pedal test start modes, as well as the anti scald safety design, can effectively ensure the convenience and safety of user use

4. Precision mechanical design is adopted, and the aluminum can sealed heating block ensures the uniformity of heating on the heating surface. The cylinder controls the lifting of the heating block to evenly apply pressure on the thermosensitive material

5. The downward cylinder design not only ensures the stability of the instrument during operation, but also effectively avoids pressure fluctuations caused by heating

6. Both the upper and lower heating blocks can independently control the temperature, providing users with more combinations of experimental conditions

7. Bottom mounted dual cylinder synchronous circuit further ensures uniform pressure distribution on the heating surface

8. The extended heating block can meet the needs of heating large or multiple samples simultaneously, and supports customization of special heating styles.

9. Configure foot switches to ensure safe user operation

10. The pneumatic control components have high precision, and the entire set adopts internationally renowned brands

11. Anti scalding design and leakage protection design for safer operation

12. The heating element is carefully designed, with uniform heat dissipation and long service life

13. Specially optimized and designed operation panel based on principles of ergonomics for convenient operation

14. One temperature can be set for each experiment

Operation usage:

1. Connect the compressed air pipe to the compressed air inlet on the left side of the instrument;

2. Connect the foot switch to the left side connection of the instrument;

3. Connect the power cord socket to the power inlet on the left side of the instrument;

4. Prepare thermosensitive materials;

5. Inject compressed air and use the adjusting handle to adjust the pressure to a value that can bring the upper and lower heating blocks together, usually 0.18-0.30 Mpa;

6. Turn on the power switch on the left panel;

7. Turn the heating switch of upper heating block 12 and lower heating block 11 to ON;

8. Set the temperature controller to the desired temperature;

 

9. Take about 10-30 minutes to stabilize the set temperature;

10. Set the timer to the desired time,


全國統(tǒng)一服務(wù)電話

0531-85809007

電子郵箱:2289528882@qq.com

公司地址:山東濟(jì)南市槐蔭區(qū)新沙工業(yè)園三街17號

業(yè)務(wù)咨詢微信

91免费视频高清在线观看| 1204国产成人精品视频| 激情综合五月天开心久久| 老司机午夜福利视频免费| 亚洲av无码乱码在线观看裸奔| 久久综合视频网| 亚洲av超碰爽死狠狠热| 国产亚洲欧美日韩激情一区| 亚洲国产精品第二在线播放| 久久久久精品亚洲中文字幕| 91精品国产综合久久久蜜| 波多野结衣无码视频一区| 国产精品久久久久久久欧美| 琪琪午夜伦理影院人妻秘书| 性色av极品无码专区亚洲| 精品欧美一区二区三区久| 一本大道东京热无码av| 性做久久久久久| 在线观看国产精品日韩av| 国产av一区二区| 俺来也六月噜噜噜久久久| 国语对白刺激真实精品| 无码毛片aaa在线| 国产精品你懂的在线播放| 51午夜 精品免费福利| caob视频在线666| 国产日韩综合一区二区性色av| 国产精品电影一区二区三| 亚洲国产成人久久精品不卡| 久久久久久高清无码视频| 九九热这里只有黄色精品| 人人妻人人澡人人爽精品欧美| 国产亚洲精品综合一区91| 亚洲自偷自拍另类12p| 亚洲精品中文字幕中文字幕| 久久99国产精品二区不卡| 无码一区二区三区蜜桃大 | 欧美 亚洲 激情 综合| 亚洲国产高清不卡一区二区| 国产台湾黄色av一区二区| 国内一区二区三区伦理片|